產(chǎn)品名稱(chēng) : FSK-1614F
類(lèi)型 : 壓電蜂鳴器
驅(qū)動(dòng)方式 : 有源蜂鳴器
工藝 : 插針?lè)澍Q器
尺寸范圍 : 15-20mm
A. SCOPE 
This specification applies magnetic buzzer, FSK-1614F
B. SPECIFICATION
| No. | Item  | Unit  | Specification  | Condition  | 
1  | Oscillation Frequency  | KHz  | 4.0 ± 0.5  | |
2  | Operating Voltage  | VDC  | 3 ~16  | |
3  | Rated Voltage | VDC  | 12  | |
4  | Current Consumption  | mA  | MAX. 30  | at Rated Voltage  | 
5  | Sound Pressure Level  | dB  | MIN. 90  | at 10cm at Rated Voltage  | 
6  | Tone/Pulse Rate  | Single  | ||
7  | Operating Temperature  | ℃  | -40 ~ +85  | |
8  | Storage Temperature  | ℃  | -50 ~ +95  | |
9  | Dimension  | mm  | Φ15.4x H13.8  | See appearance drawing  | 
10  | Weight (MAX)  | gram  | 2.5  | |
11  | Housing Material  | PPO( Black )  | ||
12  | Leading Pin  | Tin Plated Brass(Sn)  | See appearance drawing  | |
13  | Environmental    | RoHS  | 
 
C. APPEARANCE DRAWING  
 
Tol : ± 0.5     Unit: mm
D.TESTING METHOD    
Standard Measurement conditions
Temperature:25±2℃  Humidity:45-65%
Acoustic Characteristics:
The oscillation frequency, current consumption and sound pressure are measured by the measuring instruments shown below
 
In the measuring test, buzzer is placed as follows:
  
E. VOLTAGE / CURRENT / SOUND PRESSURE CHARACTERISTICS
F. RELIABILITY TEST
NO.  | ITEM  | TEST CONDITION AND REQUIREMENT  | 
1  | High Temperature  | After being placed in a chamber with 95  | 
2  | Low Temperature  | After being Placed in a chamber with -50  | 
3  | Humidity Test  | After being Placed in a chamber with 90-95% R.H. at 40  | 
4  | Temperature Cycle  | The part shall be subjected to 5 cycles. One cycle shall be consist of:   | 
5  | Drop Test  | Drop on a hard wood board of 4cm thick, any directions ,6 times, at the height of 75cm .  | 
6  | Vibration Test  | After being applied vibration of amplitude of 1.5mmwith 10 to 55 Hz band of vibration frequency to each of 3 perpendicular directions for 2 hours .  | 
7  | Solderability  | Lead terminals are immersed in rosin for 5 seconds and then immersed in solder bath of +300  | 
8  | Terminal Strength  | The force of 9.8N(1.0kg) is applied to each terminal in axial direction for 10 seconds.  | 
TEST CONDITION. 
Standard Test Condition        :      a) Temperature : +5 ~ +35℃  b) Humidity : 45-85%        c) Pressure : 860-1060mbar 
Judgment Test Condition      :      a) Temperature : +25 ± 2℃     b) Humidity : 60-70%        c) Pressure : 860-1060mbar 
 
G. PACKING STANDARD

聯(lián)系人:吳經(jīng)理
手機(jī):15722819198
電話(huà):
傳真:
郵箱: